CEB Press/Manufacturing Instructions/Detroit Fab Lab Solenoid Driver v2

From Open Source Ecology

Jump to: navigation, search

< previous version

Contents

[edit] Part Information

[edit] Tools

[edit] Materials

[edit] Steps

Circuit Etching Guide

Circuit Printout Diagram

Detoirt2sdiodeinfo.jpg

[edit] Assistance

[edit] OLD

Detroit2s.png

Detroit2sprint.png

[edit] Upgrades

[edit] 1

Field testing at Factor e Farm in 2011 has shown that twigs and rocks can jam the soil loading drawer if these are not crushed by the scissor action of the drawer. In the case of a jam, we uploaded the CEB testing code interface to move the drawer and get it unstuck - by computer control via USB cable. This is time consuming, so the next iteration should include manual bypass toggles on the controller board itself, so the user can move the drawer manually as needed. This applies to both the primary and secondary cylinder.

To do this, a simple toggle switch such as the reset switch should be placed between the 5V power and the digital output (d9 or d10) pin corresponding to the left (ejection) motion of the secondary cylinder. This is not necessary for the main cylinder, which has 20 tons of force. This is also not necessary for the right motion of the secondary cylinder, since such motion is already present upon power cycling of the controller.

[edit] Implementation

Do we need just a connection to be closed between 5V and the d9 or d10? An?y resistors in between?

how about a "garage door" button. if its running and you push it it will stop. push it again it goes in reverse. push it again it stops. push it again it continues along again. if we had a button that connected one of the digital channels to the ground would that be sufficient to trigger the software? we could put a button on the board or have a terminal wired to an external box button. --Dorkmo 04:15, 3 December 2011 (CET)

[edit] Resolved

The initialization sequence which moves the secondary cylinder to the left in addition to the right addresses the issue of jams, without the solenoid manual button on the controller.

[edit] 2

For full manual testing of hydraulics without using a control computer, 5 of these manual toggles should be applied, one for each hydraulic channel.


Standalone Version for use in other projects